OPERATION: Water
Water enters the machine through the 3/8" male
flare at the rear of the cabinet, goes to the water
reservoir which it enters through the float valve.
The water then goes out the bottom of the
reservoir tank to the bottom of the evaporator.
Reservoir overflow or evaporator condensation is
routed to the drain. Water cooled models have a
separate water circuit for the cooling water: it
enters the fitting at the rear, goes to the water
regulating valve, then to the water cooled
condenser and down the drain.
NME954 & FME1204
May 2001
Page 14
Evaporator
Drain
Water Level
Evaporator
Ice
Chute
Drain
WATER SCHEMATIC
Reservoir
Water Inlet
Evaporator Inlet