Refer the wiring diagram as needed.
If the machine is switched off at the master
switch, but is otherwise ready to go, switching
the master switch to ON does the following:
The bin empty light on the circuit board
goes on
There is a 15 second delay
If there is enough water in the reservoir, the
circuit board will allow the machine to start
up.
Start up consists of:
The liquid line relay and auger motor relay
become energized, connecting power to the
liquid line solenoid coil and to the windings
of the auger motor.
The liquid line solenoid opens, raising the
low side pressure.
The pump down control closes.
The auger motor starts, and the centrifugal
switch closes, connecting power to the
compressor contactor coil.
The contactor is energized, connecting
power to the compressor, and the
compressor starts.
As ice goes past the ice level sensors, the
bin empty light will stay on, and the
machine will continue to run, unless the ice
stays between the sensors for more than
15 seconds (bin full). At that point, the bin
empty light goes out, and the machine
shuts down.
Shut Down consists of:
The liquid line solenoid closes, lowering the
suction pressure.
The pump down control opens.
The compressor contactor opens
The compressor stops
The auger motor is run by the circuit board
for 2.5 more minutes, clearing out ice in the
evaporator, and then
The auger motor relay opens, and the
auger motor stops.
If the ice level sensor is clear (bin empty) for
more than 15 seconds, the machine will start
up again.
Another purpose of the circuit board is to turn
the machine off if there is not enough water in
the machine.
When the water level in the reservoir falls
below the water level sensor, the machine
will "shut down"
When the water refills the reservoir, the
machine will start up again.
Separate from the circuit board:
The high pressure control will stop the
machine immediately if it opens. It is
manually reset at the control and at the
reset switch on the circuit board.
The spout switch will stop the machine
immediately if it opens. It is a manual reset
at the reset switch on the circuit board.
The master switch is the manual control for
the complete machine, but it is not a
service disconnect.
ELECTRICAL SEQUENCE
NM650R
December, 1988
Page 18
Vedere la pagina 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 37 38

Commenti su questo manuale

Nessun commento

Ge-industrial-solutions Remote Racking Operator: Low Voltage AKR Circuit B manuals

Owner’s manuals and user’s guides for Equipment Ge-industrial-solutions Remote Racking Operator: Low Voltage AKR Circuit B.
We providing 1 pdf manuals Ge-industrial-solutions Remote Racking Operator: Low Voltage AKR Circuit B for download free by document types: User Manual






More products and manuals for Equipment Ge-industrial-solutions

Models Document Type
AF-600 FP Fan and Pump Drive (460V_575V 150HP and User Manual   GE Industrial Solutions AF-600 FP Fan and Pump Drive (460V_575V 150HP and above) User Manual, 175 pages
A Series Lighting Control Panelboards DB25 Connect User Manual   GE Industrial Solutions A Series Lighting Control Panelboards DB25 Connector cable User Manual [en] [es] [fr] , 1 pages
POWER LEADER ModBus Monitor User Manual   GE Industrial Solutions POWER LEADER ModBus Monitor User Manual, 68 pages
Double-Throw Safety Switch, NEMA 3R User Manual   GE Industrial Solutions Double-Throw Safety Switch, NEMA 3R User Manual, 2 pages
Power-Vac ML-20 Mechanism User Manual   GE Industrial Solutions Power-Vac ML-20 Mechanism User Manual, 40 pages
Spectra K-Frame MCCB with microEntelliGuard trip u User Manual   GE Industrial Solutions Spectra K-Frame MCCB with microEntelliGuard trip unit User Manual, 8 pages
Record Plus FG600 with SMR1 or SMR2 Trip Unit User Manual   GE Industrial Solutions Record Plus FG600 with SMR1 or SMR2 Trip Unit User Manual, 8 pages
ZNET901 User Manual   GE Industrial Solutions ZNET901 User Manual [en] [es] [fr] , 10 pages
EQW010-040 Series (Eighth-Brick) User Manual   GE Industrial Solutions EQW010-040 Series (Eighth-Brick) User Manual, 28 pages
Spectra Series ACT Transient-Voltage User Manual   GE Industrial Solutions Spectra Series ACT Transient-Voltage User Manual, 4 pages
ZBTE Series User Manual   GE Industrial Solutions ZBTE Series User Manual [en] [es] [fr] , 20 pages
Control System Toolbox For AV-300, DV-300, AV-300i User Manual   GE Industrial Solutions Control System Toolbox For AV-300, DV-300, AV-300i (AVDV Series) Drives User Manual [en] , 82 pages
Record Plus Cable Operating Mechanism: FC100, FE25 User Manual   GE Industrial Solutions Record Plus Cable Operating Mechanism: FC100, FE250 User Manual [en] , 8 pages
Cable Operator Mechanisms for Thermal-Magnetic E15 User Manual   GE Industrial Solutions Cable Operator Mechanisms for Thermal-Magnetic E150 and Spectra SE150, SF250, and SG600 MCCBs User Manual [en] [es] [fr] , 6 pages
CLP0212 User Manual   GE Industrial Solutions CLP0212 User Manual, 15 pages
DCPower User Manual   GE Industrial Solutions DCPower User Manual [en] [es] [fr] , 1 pages
Austin Lynx II 12V SIP User Manual   GE Industrial Solutions Austin Lynx II 12V SIP User Manual [en] [es] [fr] , 19 pages
ProTrip Conversion Kits K-225, K-600, K-800, K-160 User Manual   GE Industrial Solutions ProTrip Conversion Kits K-225, K-600, K-800, K-1600 User Manual, 24 pages
AF-600 FP Panel Through Mount Kit User Manual   GE Industrial Solutions AF-600 FP Panel Through Mount Kit User Manual, 12 pages
EntelliGuard G Envelope 3, drawout, For 6000A UL _ User Manual   GE Industrial Solutions EntelliGuard G Envelope 3, drawout, For 6000A UL _ 5000A ANSI User Manual [en] , 2 pages